+ Quick install cheat sheet + Entering programming mode To enter programming mode, you must use an alpha keypad and all partitions on the system must be disarmed. Press 8, installer code, 00 (default 4321). The keypad should read ”SYSTEM PROGRAMMING”. If you are using an alpha keypad that will not be staying on site, you must delete the serial number when finished programming (Shortcut Number 10000, find the matching serial and then press D to delete). Or before entering programming mode press 8, installer code, 02 to enroll the keypad as a programming keypad only. + Programming a Concord 4 To programme a Concord 4, you must have an alpha keypad and all partitions on the system must be disarmed.

Once in programming mode, you can use A/B to scroll up and down through the menus and # to select/save or * to go back. 1 and 2 are used to toggle options (1) on, or (2) off, and D is used to delete fields. There are also shortcuts which work similar to programming locations, just type in the shortcut and it will jump you to that option, which is much easier than going up and down through the menus. + Exiting programming mode To exit programming mode press * repeatedly (could be once or could be 4 times depending where you are in programming) until the panel reads ”SYSTEM PROGRAMMING”. Next, press up (A) and it should now read ”EXIT PROGRAMMING”, press # to select. + Defaulting the panel To default the panel, get into programming mode, 8, installer code, 00. How To Crack Atn Iptv Arabic there.

Concord 4 Master Code Reset

Sep 11, 2013 Concord 4 Change Master Code - Duration. ProTec Home Security Systems Changing the Master Code. Oct 25, 2010 Hello everyone! Im having some issues with changing my system master code. I go into the settings and reset the 'System Master' code but I.

Once the system reads ”SYSTEM PROGRAMMING”, use B to scroll down until it reads ”CLEAR MEMORY”, press # then re-enter the installer code. The system will completely default and you will have to reprogramme it. The installer code will become 4321 and the master code will become 1234. If you have lost the installer code, you will need to replace the panel. + Zone wiring details All hardwired zones are single EOL with a 2.2K Ohm resistor. This cannot be changed or removed in programming. + Programme a hardwired zone To programme a hardwired zone, you must learn the zone into the panel.

Every sensor must be learnt in, wireless or hardwired. Usually the main boards 8 zones are already learnt in to zones 1-8, respectively. If you are adding a zone expander or wireless zones, every zone must be learnt in individually. Learn sensors SHORTCUT 080 Select learn sensors, then select the zone you wish to add. It will now ask you to select a partition (1-6) and then a sensor group (zone type). If you are learning in multiple zones, I would recommend learning them all in as sensor group 13 (standard perimeter zone) then changing them individually in the edit sensors menu later. This can make testing easier, as sensor group 17 (standard motion sensor zone) will not show up as an open zone when the panel is disarmed.

Sensor groups: • 00 = Panic alarm • 10 = Entry zone • 13 = Instant perimeter • 17 = Interior sensor • 26 = Fire zone Once the keypad reads ”TRIP SENSOR XX”, simply trip the zone that you wish to learn. One beep indicates the zone has learnt in and the keypad should jump to the next available zone to learn. You can easily shoot yourself in the foot when learning wired sensors in, especially if you are working in a busy building. I would suggest tripping each zone at the head end or expander by shorting out the zone terminal with a resistor. This way there is less room for error, as people move around in front of motions, etc. Otherwise, you may end up with your zone 5 learnt in as zone 2 and a huge headache.

• [TRIP SENSOR 04] • Short the zone 4 and common with a 2.2k Ohm resistor • BEEP • [TRIP SENSOR 05] • Short out the next zone on the board, etc + Programme a wireless zone To programme a wireless zone, you must learn the zone into the panel. Every sensor must be learnt in, wireless or hardwired. Learn sensors SHORTCUT 080 Select learn sensors, then select the next empty zone you want to use as wireless. It will now ask you to select a partition (1-6) and then a sensor group (zone type). If you are learning in multiple zones, I would recommend learning them all in as sensor group 13 (standard perimeter zone) then changing them individually in the edit sensors menu later. This can make testing easier, as sensor group 17 (standard motion sensor zone) will not show up as an open zone when the panel is disarmed.

Sensor groups: • 00 = Panic alarm • 10 = Entry zone • 13 = Instant perimeter • 17 = Interior sensor • 26 = Fire zone Once the keypad reads ”TRIP SENSOR XX”, simply tamper the device that you wish to learn. One beep indicates the zone has learnt in and the keypad should jump to the next available zone to learn. • [TRIP SENSOR 09] • Tamper the wireless device • BEEP • [TRIP SENSOR 10] • Tamper the next device, or press # + Install a zone expander Adding a zone expander onto the system is simple, wire it into the keybus, there is no addressing needed.

The snapcard expander (60-757) is an 8 zone expander that plugs into the main board on the right hand side. On the snapcard, only 6 zones are available to use for any sensor and the other 2 are dedicated as fire zones.

The superbus 2000 expander (60-774) must be wired into the keybus and has 8 zones that can be used. The zones on the expander need to be learnt in, individually. The zone expander itself does not represent a zone range like with other alarm panels. To add the zone to the panel go to learn sensors SHORTCUT 080. Select a spare zone you want to be the first zone on the expander. To make things easier, it is best to select a zone number with 7 spare zones following it.

Select a partition and sensor group. Then use a resistor to short the first zone terminal on the zone expander. • [TRIP SENSOR 09] • Short the zone 1 and common terminals on the expander with a 2.2k Ohm resistor • BEEP • [TRIP SENSOR 10] • Short zone 2 and common on the expander with a resistor • Continue to learn in all zones on the expander + Zone text If there is an alpha keypad staying on site, it is always good practice to programme in zone names. Select sensor text SHORTCUT 081 then scroll to select which zone you wish to program.

Once selected, it will ask you for an item number from the word library. Each zone can have up to 16 items.

An item is a word or a letter; letters are used if you wish to make your own word, not from the library. Here are some commonly used words: • Item 017 = Back • Item 050 = Door • Item 058 = East • Item 061 = Entry • item 077 = Front • Item 119 = Motion • item 121 = North • Item 163 = Smoke • Item 166 = South • Item 172 = Tamper • Item 182 = West • Item 183 = Window + Delete a zone Deleting a zone is a simple one step process. Enter SHORTCUT 082, enter the zone number then press #. + To change/add user codes The master code can add/change/delete all regular user codes and partition master codes. You must change codes from the user menu. To gain access into the user menu, press 9, master code ( default is 1234). The panel should read ”TIME AND DATE”.

From here, you can use A/B to scroll up and down and select the user code menu, where you can scroll through regular users, partition masters, and master code. Select a code to alter.

Enter the new 4-digit code. + To delete user codes Press 9, master code ( default is 1234). The panel should read ”TIME AND DATE”. From here, you can use A/B to scroll up and down and select the user code menu, where you can scroll through regular users, partition masters, and master code. Select a code to alter. If you wish to delete the code, just enter the system master code again instead of a new code. The system will recognize the master code and delete the current code.

+ Partitioning users Users can have access to more than one partition. To assign partitions you must be in user menu programming.

From normal run mode: • Press 9, master code ( default is 1234), 030 • Now enter the 3-digit user number you wish to change • Press 5, for partition menu • Toggle on/off the partitions the user can access, 1-6 • Press * to save and then 00, # to exit + Lost codes If you have lost the system master code, you have 2 options. First, you can attempt the back door into user programming using 9, installer code, 3, #. If this does not work, you have to default the panel. To default the panel, get into installer programming (8, installer code, 00) and when it shows ”SYSTEM PROGRAMMING”, use B to scroll down until it reads ”CLEAR MEMORY”, then press # and re-enter the installer code. The system will completely default and you will have to reprogramme everything. The installer code will become 4321 and the master code will become 1234. If you have lost the system installer code, there is no way to access programming without the installer or dealer code.

If you have no luck, you will have to replace the panel. + Phone numbers • Shortcut 01000 phone number 1 • Shortcut 01010 phone number 2 (backup number 1) • Shortcut 01020 phone number 3 (backup number 2) • Shortcut 01090 downloader phone number Enter in the phone number that the central station has given you for the panel to dial; use numbers 0-9, C will enter a pause and holding down 7 or 9 will give you a * or #. You can use phone number 2 and 3 as backups if you have more than one number. If you use backup numbers, the panel will attempt to dial out 16 times alternating between the numbers. If you do not programme numbers 2 and 3, it will attempt to dial out 8 times on phone number 1 before generating a communication fail trouble. To delete a phone number, press D from within the programming field and then # to save.

• HEX C = 3 second pause • Hold down 7 = * • Hold down 9 = # If your Concord will not be reporting, you may want to remove any comms programming so a ”FAIL TO COMMUNICATE” does not appear. By default the comms are not setup; however, programme these few shortcuts to be sure it is disabled: • Shortcut 0010 D to delete • Shortcut 01000 D to delete • Shortcut 01010 D to delete • Shortcut 01020 D to delete • Shortcut 02001 1 = Off If you have no phone line wired in, you must program the system so that it will not show a ”PHONE LINE FAIL” fault. • Shortcut 0213 D to delete + Account numbers If using more than one partition, be sure to enter an account number for each partition; they can be the same account number. To program HEX digits, just hold the number key down.

+ Troubles Here are a list of faults and how to fix them. A fault is indicated by the keypad emitting 5 short beeps every minute. There should also be a message on the keypad. To silence the trouble beeps, just press * and wait for the keypad to scroll through everything. The trouble will only silence for 10 hours and return if the fault is not fixed.

AC POWER FAILURE: Pretty simple, there is no AC getting to the panel, check your transformer and wire. LOW BATT: System low battery, replace the backup battery or recharge it if the power has been off too long. It should charge up and clear the fault within 24 hours. If not, look at replacing the battery and remember to check the charging voltage coming out of the battery leads. SENSOR SUPERVISORY: The panel has not had a check-in signal from the zone. This fault is for wireless zones.

The most common cause is that the batteries are too low and need replacing. If it's a keyfob or other zone that shouldn't be sending a supervised signal by itself then it should be reprogrammed.

A keyfob should be sensor group 1. View all Sensor Groups If the trouble still persists, you may need to replace the sensor. SENSOR TROUBLE: A sensor trouble can often be a wiring fault.

Typically the zone should be normally closed, all wired zones need a 2K Ohm resistor across the zone when it is closed and an open loop when the zone is open or activated. A sensor trouble can be caused by a short on the zone. Check your wiring and delete the zone and relearn it to be sure it is NC. SENSOR XX LOW BATTERY: Another wireless zone fault. Replace the batteries in the identified zone. The trouble may take a while to clear.

Try opening and closing the zone then press 1, installer code. If the trouble is still there, power cycle the panel and test the zone again to make sure the fault does not come back. SENSOR XX TROUBLE: Identify which zone is showing the tamper then check if the cover is on straight.

If it's a hardwired sensor, double check your wiring and resistor value (all wired zones need a 2K Ohm resistor across the zone). If it's a wireless zone, pull the sensor apart and identify the micro-switch/spring that works as the tamper and see if it is closing correctly. You should be able to take the wireless sensor to the keypad, hold the tamper shut with your hand and press 1, installer code. If the fault does not clear, it may be a faulty sensor. PHONE FAILURE TROUBLE: This fault appears when the panel does not see 50V (or thereabouts) on the red/green terminals (25 and 28). Check your phone line wiring. If you are not wiring in a phone line and don't want the trouble displayed then follow the instructions under the Comms section above.

RECIEVER INTERFERENCE/FAILURE: If the receiver has not received a signal from any wireless device for 2 hours or something is jamming the signal, this fault will appear. Try and force a wireless zone to send a signal and see if the panel responds. Check the location of the panel, as the receiver is built in. Make sure the antennas have clear room and should have the plastic covers installed around them.

MEMORY FAILURE: This can be a checksum/watchdog issue with the EEPROM. Try a power cycle and if the issue still remains, you may have to replace the board. AUXILIARY PHONE TROUBLE: GSM problem. AUX POWER FAILURE: Check the voltage coming out of Terminals 3 and 4. If it's lower than 12V, pull all the wires out and measure it again.

If it increases then some device is pulling the voltage down. Add the device wires back in one at a time measuring to see which one is pulling it down. Once identified, check the wiring at the device as it could be a cable fault. BUS FAILURE UNIT XX: The panel has lost communication with a bus device. Go into programming and check all bus device serial numbers learnt in and see which one is missing.

If you were using a temporary keypad for programming and have removed it, you may have to go back into programming and delete the serial number. Shortcut 10000 D to delete. GROUND FAULT: A ground fault can appear if one of your devices has a short on it. Remove each of your zones and bus devices one at a time until the ground fault clears. Once you have identified where the fault is coming from, you can trace the cable. A ground fault can also be caused by a high voltage spike on the telco line.

ARMED TO PROGRAMMING: This message will show up and the keypad will be unresponsive. This is caused when you disconnect your programming keypad without first exiting programming mode. This will also send a supervisory trouble signal to the monitoring station, if monitored. + Speaker The speaker output cannot be programmed and is set as a speaker driver for partition 1 only. You cannot connect piezos or bells to this output.

The output can drive a single 8 Ohm speaker or a multiple speaker circuit of 8 Ohms or higher. When connecting two or more speakers, wire them in series. Wiring speakers in parallel can permanently damage the panel. + Output 1 and 2 Output 1 triggers positive when activated and output 2 triggers negative. + Disarm • 1 + code = Disarms the partition. + Arm stay • 2 + code = Arms the partition to stay mode.

+ Arm away • 3 + code = Arms the partition to away mode. An entry zone must be tripped within the exit delay, this cannot be disabled. + Arm no delay • 2/3 + code + 4 = Arms the system to stay/away with no delay.

Use this to arm in away mode without having to trip an entry zone. + Silent arm • 5 + 2/3 + code = Silently arms the partition to stay/away. + Chime • 7 + 1 = Turns the chime on/off.

+ Change partitions • 7 + 4 + 1/2/3/4/5/6 = Changes the keypad to partition 1/2/3/4/5/6. Partition security must be off in shortcut 0004 • 7 + 2 + partition number = Changes to another partition. Partition security must be off in shortcut 0004. + Bypassing • Pressing # + code + sensor number = Bypasses the sensor. Nhl 2002 Ps2 Download Games on this page. Alternatively, arm the system when the zone is open and press #. + View status • Pressing * = Check system status and memory. • Pressing * twice = Check full status.

+ View memory • 7 + 6 = Check full memory.